144/407
Connection points
6.2

KCU02 connection points

6.2.1

Positions of the connection points

Figure
Bosch Rexroth AG R911335703_Edition 04
Element Significance
1
Equipment grounding
conductor
2
Joint bar equipment
grounding conductor
F4
Fuse output X54 (L+)
F5
Fuse output X54 (L-)
LEDs
H49: Safety
H52.1: E-Stop
H52.2: Power Supply
H52.3: Warning
H52.4: DC Bus In
H52.5: Drives
H53: 42 V Out
H54: DC Bus Out
24 V, 0 V Control voltage
L+, L-
DC bus
X1
Module bus
X29.1
Multi-Ethernet
X29.2
X49
Safety technology
X50
E-Stop
X52
Status messages
X53
42 V, 0 V
X54
DC bus, equipment
grounding conductor
Tab. 6-2:
Connection Points KCU02
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Notes
For connection to the equipment grounding
system
For connection to neighboring device
(part of basic accessory HAS01)
30 A
30 A
Diagnostic Displays
For connection to supply unit via contact bars
(part of basic accessory HAS01)
For connection to supply unit via contact bars
(part of basic accessory HAS01)
Keep ribbon cable in parking position, when
there is no connection to neighboring device.
Signals are looped through
L3 (Safe Torque Off)
E-Stop input
For exchanging status messages
42 V output; control voltage supply
DC bus output; power supply