Interconnection Diagrams For Ready-Made Hybrid Cables Incl. Communication; Kcu - Ksm/Kms - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
5.9.5
Interconnection diagrams for ready-made hybrid cables incl. commu‐
nication

KCU - KSM/KMS

Applies to: RKH0311, RKH0411, RKH0511
KCU plug-in connector
RHS0005/C03
Coding at KSM/KMS plug-in connector
Cable type
RKH0311
RKH0411
RKH0511
1)
R-End plug-in connector for RKH0311, RKH0411
2)
R-End plug-in connector for RKH0511
4)
Picture shows coding with view to mating side
5)
The coding profile ensures the downward compatibility of the
hybrid cable for KSM01/KMS01
Tab. 5-25:
Parts of ready-made hybrid cables from KCU to KSM/KMS
Technical data of the components
Bulk cable
REH0800
Interconnection diagram
L-End
RHS0005
R911335703_Edition 04 Bosch Rexroth AG
123/407
KSM/KMS plug-in
connector
RHS0011/C03
1)
RHS0016/C03
2)
4)
R-End
RHS0011, RHS0016
Locking pin
Coding profile
5)

Advertisement

Table of Contents
loading