Kcu02; Mounting Depths; Touch Guard - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
9.4

KCU02

9.4.1

Mounting depths

Adjusting Mounting Depths
9.4.2

Touch guard

HMV01 and HCS03 devices have greater mounting depths than the drive
connection box KCU. For connecting the drive connection box KCU to an
HMV01 or HCS03 device, you must therefore use the control cabinet adapter
HAS03.1-002
which compensates the different mounting depths.
WARNING
The appropriate touch guard must be mounted for each device following
connection work.
Never operate the device without mounted touch guard.
Never mount a damaged touch guard.
Immediately replace a damaged touch guard by an undamaged touch
guard.
Keep the cutouts at the touch guard as small as possible. Only remove
the cutouts if necessary.
Cutouts at the touch guard
If the DC bus and the control voltage are connected via contact bars, only
cutout A may be removed from the touch guard.
If the DC bus and the control voltage are connected via cables (e.g., in the case
of multiple-line arrangement), cutouts A, B and C may be removed from the
touch guard.
At the first and last device in a line of interconnected devices, cutouts may not
be removed from the outer side of the touch guard.
Tab. 9-3:
Cutouts at the touch guard
Mounting and installation
Lethal electric shock by live parts with more
than 50 V!
R911335703_Edition 04 Bosch Rexroth AG
283/407

Advertisement