348/407
Commissioning, operation, diagnostics and maintenance
Color / flashing pattern
Off
Flashing green
Permanently lit green
Flashing red-green
Flashing red-green
Flashing red-green
Flashing red
Permanently lit red
Bosch Rexroth AG R911335703_Edition 04

LED H25, displays

1)
Safety technology status
(Safety Supervisor State / Event)
Not active
Safety bus communication not
configured
Active, no connection (safety default)
Active, at least one safe connection
Waiting for TUNID
Self test and initialization
Identifying the axis identifier
Indentifying the safety technology
TUNID
not yet set
2)
Abortion of connections
Critical error
1)
Flashing pattern: One square corresponds to a duration of
250 ms; the arrow marks the end of a cycle; abbreviations on
the squares: GN = LED permanently lit green, RD = LED per‐
manently lit red, -- = LED is off
2)
TUNID = Target Unique Network Identifier
3)
The LED display is only active with safety bus communication
via the master communication
Tab. 11-5:
LED display
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
3)
Connection status
Not ready
Safety bus communication not
configured
Ready and no active connection
Ready and at least one active connection
2)
Waiting for TUNID
Self test and initialization
Identifying the axis identifier
-
-
Faulty abortion of at least one active
connection
Critical connection error
3)
2)

Advertisement