Maintenance; Maintenance Of The Motor Component; General Information; Cleaning - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
11.5

Maintenance

11.5.1

Maintenance of the Motor Component

General Information

Cleaning

Bearings

Connection Cables

Commissioning, operation, diagnostics and maintenance
The motors operate in a maintenance-free way within the given operating
conditions and service life. However, operation under unfavorable conditions
can lead to limitations in availability.
Increase the availability with regular preventive maintenance measures.
Observe the information in the maintenance schedule of the machine
manufacturer and the maintenance measures described below.
CAUTION
Before beginning to work, let the motors cool down. The thermal time
constant specified in the Technical Data is a measure for the time required
for cooling down. Cooling down can require up to 140 minutes!
Do not work at hot surfaces.
Wear safety gloves.
Excessive dirt, dust or shavings may affect the function of the motors
adversely, may in extreme cases even cause a failure of the motors. For that
reason, you should clean the cooling ribs of the motors in regular intervals (at
the latest, after one year is over).
The nominal service life of the bearings is L10h > 30000 h (according to
DIN ISO 281, ed. 1990), if the permissible radial and axial forces are not
exceeded.
The motor bearings should be replaced, if
the nominal bearing service life has been reached
running noise can be heard
We recommend that you have the bearings replaced by Rexroth.
Check connection cables for damage in regular intervals and replace them, if
necessary.
Check any optionally present flexible cable tracks for damage and replace
them, if necessary.
WARNING
Do not repair any connection cables provisionally. If the slightest damage is
detected in the cable sheath, you must immediately put the installation out of
operation and replace the connection cable.
Check the equipment grounding conductor for proper connection and tight fit
in regular intervals.
Risk
of
burns
by
hot
temperatures of more than 100 °C!
Danger to life by live parts with more than
50 V!
R911335703_Edition 04 Bosch Rexroth AG
361/407
surfaces
with

Advertisement

Table of Contents