HUAWEI TP3106&TP3118&TP3118S
Commissioning Guide
2.
3.
l To set the red gain (RGain VAL) to 209, run camera setc500CameraParam Redgain:209
----End

7.1.1 Saving Camera Parameter Settings

After all camera parameters are set, do the following to save the parameter settings:
Step 1 Telnet to each telepresence codec.
To telnet to the telepresence codec whose IP address is 10.11.250.61, do the following: Choose
Start > Run. In the Run dialog box, enter telnet 10.11.250.61, and press Enter. On the displayed
window, enter the login name debug and password Change_Me.
The window shown in the following figure is displayed.
Issue 01 (2015-02-12)
command, do not move the camera for about five seconds; doing so may affect the blue
and red gain settings in automatic white balance mode. See the following figure.
Run camctrl camzoomsetting inquire on to query and record the values of the blue gain
and red gain in automatic white balance mode. Repeat the preceding operations and record
the values of the blue gain and red gain combination that produces the best color rendition.
Run camera setc500CameraParam whitebalance:4 camport:5 to change the white
balance mode to manual. This alters the settings of the blue gain and red gain. Therefore,
reset the blue gain and the red gain by running the relevant API commands based on the
values recorded in sub-step 2.
l To set the blue gain (BGain VAL) to 159, run camera setc500CameraParam
bluegain:159 camport:5.
camport:5. See the following figure.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 Appendix