2.6.4 Setting the Tabletop Display IP Addresses
Set the tabletop displays' dual in-line package (DIP) switches and IP addresses as follows. As
shown in
l
l
l
l
Figure 2-17 Tabletop displays number description
Issue 01 (2015-02-12)
Network interface
mode
Figure
2-17.
Front-row, Left tabletop display: Set all switches to OFF, and the IP address will be set to
172.16.21.30.
Front-row, Center tabletop display: Set switch 4 to ON, other switches to OFF, and the IP
address will be set to 172.16.21.31.
Front-row, Right tabletop display: Set switch 5 to ON, other switches to OFF, and the IP
address will be set to 172.16.21.32.
The second row can be done in the same manner.
NOTE
After all cables are connected, set the power switch to ON. The default IP addresses for all tabletop displays
are 172.16.21.30, as shown in