HUAWEI TP3106&TP3118&TP3118S
Commissioning Guide
The window similar to the one shown in the following figure is displayed.
Step 3 Check the settings of the auxiliary parameters.
Generally, you do not need to manually change the settings of the auxiliary parameters during
deployment. If the settings displayed in the query result are different from the default (standard)
settings, reset the parameters by running the relevant commands.
1.
2.
3.
Step 4 Set the manual focus value.
1.
2.
Issue 01 (2015-02-12)
Backlight compensation (standard value: 0)
Run the backlight command to turn on or off backlight compensation (0: off; 1: on). The
command format is as follows: camera setc500Cameraparm backlight:0 camport:5
Generally, you do not need to change the settings of this parameter.
Shutter speed (standard value: 6)
Run the speed command to set Shutter speed (value range: 1-15). The command format
is as follows:
camera setc500Cameraparm speed:6 camport:5
Note: If the screen blinks, set Shutter speed to 8.
Shutter delay (standard value: 0)
Run the slowshtlimit command to set ShutterLimit VAL (value range: 0-2). The
command format is as follows:
camera setc500Cameraparm slowshtlimit:0 camport:5
Generally, you do not need to change the settings of this parameter.
Set the focus mode to manual focus by running the following command:
camera setc500CameraParam focusswitch:1 camport:5
Set Focus VAL to the standard value 9000 by running the following command:
Camera setc500CameraParam focusval:9000 camport:5