Figure 55
7.
The engine computer checks the engine state
and fault information. The InfoCenter may
display the following messages found in the
table that follows:
Check Message and Corrective Action Table
Corrective Action: Exit the regeneration menu and run the
machine until the time since last regeneration is greater than
50 hours; refer to
Time Since Last Regeneration (page
Corrective Action: Troubleshoot the engine fault and retry
DPF regeneration.
Corrective Action: Start and run the engine.
Corrective Action: Run the engine to warm the coolant
temperature to 60°C (140°F).
Check Message and Corrective Action Table
(cont'd.)
g224406
Corrective Action: Change the engine speed to low idle.
g224406
Corrective Action: Troubleshoot the engine computer
condition and retry DPF regeneration.
8.
The InfoCenter displays the home screen and
the regeneration acknowledge icon
appears in the lower right corner of the screen
as the regeneration processes.
30).
Note:
runs, the InfoCenter displays the high
exhaust-temperature icon
9.
When the engine computer completes a
parked or recovery regeneration, the InfoCenter
displays A
left button to exit to the home screen.