190
Fault
Code
3038
3039
3101
3102
3201
3202
3203
3204
3205
3206
3207
Diagnostics
Fault Name
Fault
In Panel
NO DRIVE
No drive data available
DATA
(Group 112)
FBA PAR
Non embedded fieldbus
CONF
has detected an error in
Group 51 parameters
SFLASH
Internal checksum error N/A
CORRUPT
PMAP FILE
Parameter file is corrupt
T1
T1 program cycle is
OVERLOAD
overloaded
T2
T2 program cycle is
OVERLOAD
overloaded
T3
T3 program cycle is
OVERLOAD
overloaded
STACK
Program cycle is
OVERFLOW
overloaded
UNKNOWN
Bypass control board
CB
type is unknown.
UNKNOWN
Drive reports rating not
DRIVE
found in bypass
software
UNKNOWN
N/A
BYPASS
ACH580 E-Clipse bypass and packaged drive user manual
Possible Cause
Bypass not able to
extract drive data on
initial power up due
to:
Bad cable/
connection between
drive and bypass.
Drive parameter
95.21, bit 5 not set
for Bypass present.
Incorrect settings in
Group 51
N/A
N/A
N/A
N/A
Firmware is not
compatible with
control board in
RBCU.
Drive does not match
drives configured in
bypass RBCU
N/A
Corrective Action
Proper seating of cable in
drive and RBCU
(connector J3).
Check that drive parameter
95.21, bit 5 is set.
Verify Group 51 parameters
Cycle power
Replace RBCU
Upgrade firmware
Cycle Power
Contact ABB with information
that preceded fault
Contact ABB with information
that preceded fault
Cycle Power
Replace RBCU
Contact ABB with information
that preceded fault
Cycle Power
Replace RBCU
Contact ABB with information
that preceded fault
Cycle Power
Replace RBCU
Contact ABB with information
that preceded fault
Cycle Power
Replace RBCU
Contact ABB at
1-800-752-0696 option 1
Replace RBCU or reload with
most current firmware
Replace RBCU or load most
current firmware
Contact ABB at
1-800-752-0696 option 1
Replace RBCU or load most
current firmware