Siemens Sinumerik 840D sl Diagnostic Manual page 955

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
234999
<location>VSM: Unknown alarm
Message
New message: %1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
A fault occurred on the Voltage Sensing Module (VSM) an alarm has occurred that cannot be inter-
preted by the Control Unit firmware.
This can occur if the firmware on this component is more recent than the firmware on the Control Unit.
Alarm value (r2124, interpret decimal):
Alarm number.
Note:
If required, the significance of this new alarm can be read about in a more recent description of the
Control Unit.
Remedy:
- replace the firmware on the Voltage Sensing Module by an older firmware version (r0148).
- upgrade the firmware on the Control Unit (r0018).
235000
<location>TM54F: Sampling time invalid
Message
%1
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
POWER ON
Cause:
The set sampling time is invalid.
- not a multiple integer of the DP clock cycle.
Fault value (r0949, floating point):
Recommended valid sampling time.
Remedy:
Adapt the sampling time (e.g. set the recommended valid sampling time).
See also: p10000 (SI sampling time)
235001
<location>TM54F: Parameter value invalid
Message
%1
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The entered value is invalid.
Fault value (r0949, interpret decimal):
Parameter number with the invalid value.
Remedy:
Correct the parameter value.
235002
<location>TM54F: Commissioning not possible
Message
%1
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The commissioning mode setting was rejected because for at least one drive belonging to the TM54F,
the pulses had not been suppressed.
Fault value (r0949, interpret decimal):
Drive object number of the first drive found without pulse suppression.
Remedy:
Cancel the pulses for the drive specified in the fault value.
235003
<location>TM54F: Acknowledgement on the Control Unit is required
Message
-
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY
© Siemens AG 2009 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
SINAMICS-Alarms
2-955

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents