Siemens Sinumerik 840D sl Diagnostic Manual page 1015

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
400272
Direct keys 2 communication error, internal error code: %Z
Definitions:
Communication error between CP and PLC.
Reaction:
Alarm display.
Remedy:
Check OpKey parameter
Program Con-
Internal
tinuation:
400274
Direct keys 1 failed
Definitions:
Direct keys 1: internal timeout has expired.
Reaction:
Alarm display.
Remedy:
Check connection to direct key module
Program Con-
Internal
tinuation:
400275
Direct keys 2 failed
Definitions:
Direct keys 2: internal timeout has expired.
Reaction:
Alarm display.
Remedy:
Check connection to direct key module
Program Con-
Internal
tinuation:
400276
Pointer parameter direct keys 1 incorrect
Definitions:
Pointer incorrectly defined
Reaction:
Alarm display.
Remedy:
Correct the pointer
Program Con-
Switch control OFF - ON.
tinuation:
400277
Pointer parameter direct keys 2 incorrect
Definitions:
Pointer incorrectly defined
Reaction:
Alarm display.
Remedy:
Correct the pointer
Program Con-
Switch control OFF - ON.
tinuation:
400551
Fault on MPI/DP bus
Definitions:
Error detected on I/O bus
Reaction:
Alarm display.
Remedy:
Check I/Os, rectify I/O fault
Program Con-
Internal
tinuation:
400552
Fault on DP bus
Definitions:
Error detected on I/O bus
Reaction:
Alarm display.
Remedy:
Check I/Os, rectify I/O fault
Program Con-
Internal
tinuation:
400553
Fault on PROFINET bus
Definitions:
Error detected on I/O bus
Reaction:
Alarm display.
Remedy:
Check I/Os, rectify I/O fault
Program Con-
Internal
tinuation:
© Siemens AG 2009 All Rights Reserved