Siemens Sinumerik 840D sl Diagnostic Manual page 1003

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Remedy:
Only use addresses outside the PLC process image (e.g. >= 256) for output slots.
Enter correct basic addresses in the machine data:
- For length=1: Correct machine data MN_HW_ASSIGN_DIG_FASTOUT.
- For length=2: Correct machine data MN_HW_ASSIGN_ANA_FASTOUT.
- NCK restart
If the error cannot be eliminated by this procedure, please make a note of the error text and contact
the control system manufacturer.
Program Con-
Switch control OFF - ON.
tinuation:
380075
PROFIBUS/PROFINET: DP I/O failure bus %2 slave/device %1
Parameters:
%1 = Slave/device address
%2 = Number of the affected bus
Definitions:
Failure of a PROFIBUS/PROFINET slot used by the NCK for digital or analog I/Os.
Reaction:
Alarm display.
Remedy:
Check that the slave/device is operating correctly (all slaves/devices must be included in the bus,
green LEDs).
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
380076
PROFIBUS/PROFINET: No DO1 message frame: Bus %2 slave/device %1
Parameters:
%1 = Slave/device address
%2 = Number of the affected bus
Definitions:
Note for the system startup engineer: A PROFIBUS slave/PROFINET device used as an NCK drive
does not have a valid DO1 message frame assignment (see MD13120
$MN_CONTROL_UNIT_LOGIC_ADDRESS with the STEP 7 configuration).
This alarm is indicating, among other things, that the alarm time-of-day synchronization is not working
between the controller and this slave/device.
Reaction:
Alarm display.
Remedy:
Enter a valid value in MD13120 $MN_CONTROL_UNIT_LOGIC_ADDRESS.
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
380500
PROFIBUS/PROFINET: Fault on drive %1, code %2, value %3, time %4
Parameters:
%1 = Axis
%2 = Fault code of drive (P947(/945)/P824)
%3 = Fault value of drive ((P949/P826)
%4 = Fault time of drive (P948/P825)
Definitions:
Contents of fault memory of assigned drive.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
380501
PROFIBUS/PROFINET: Fault on bus, slave/device, DO ID %1, code %2,
value %3, time %4
Parameters:
%1 = 8 bit bus number, 8 bit slave/device number, 16 bit DO ID
%2 = Fault code of drive (P947)
%3 = Fault value of the drive (P949)
%4 = Fault time of the drive (P948)
Definitions:
Contents of the fault memory of the assigned slave/device.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
380502
PROFIBUS/PROFINET: Bus %1, slave/device %2 configuration changed
Parameters:
%1 = Bus number
%2 = Slave/device address
© Siemens AG 2009 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
Drives alarms
2-1003

Hide quick links:

Advertisement