Siemens Sinumerik 840D sl Diagnostic Manual page 1011

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
400171
Delete DB 71 in the PLC and restart
Definitions:
The DB created by the basic program and the existing DB differ in size.
Reaction:
Alarm display.
Remedy:
Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program Con-
Internal
tinuation:
400172
Delete DB 72 in the PLC and restart
Definitions:
--
Reaction:
Alarm display.
Remedy:
See the machine manufacturer's information.
Program Con-
Internal
tinuation:
400173
Delete DB 73 in the PLC and restart
Definitions:
The DB created by the basic program and the existing DB differ in size.
Reaction:
Alarm display.
Remedy:
Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program Con-
Internal
tinuation:
400174
Delete DB 74 in the PLC and restart
Definitions:
The DB created by the basic program and the existing DB differ in size.
Reaction:
Alarm display.
Remedy:
Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program Con-
Internal
tinuation:
400176
Delete DB 76 in the PLC and restart
Definitions:
The DB created by the basic program and the existing DB differ in size.
Reaction:
Alarm display.
Remedy:
Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program Con-
Internal
tinuation:
400177
Delete DB 77 in the PLC and restart
Definitions:
The DB created by the basic program and the existing DB differ in size.
Reaction:
Alarm display.
Remedy:
Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program Con-
Internal
tinuation:
400201
PLC STOP due to DB loading in the RUN state: DB%Z
Parameters:
%Z = Data block
Definitions:
An existing DB was reloaded in the RUN state.
Reaction:
Alarm display.
Remedy:
Restart required.
Program Con-
Switch control OFF - ON.
tinuation:
400202
Access error
Definitions:
The data could not be accessed.
Reaction:
Alarm display.
Remedy:
System error, contact the Siemens AG A&D MC Hotline with the error text.
Program Con-
Switch control OFF - ON.
tinuation:
© Siemens AG 2009 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
PLC alarms
2-1011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents