Siemens CPU 948 Programming Manual page 466

Simatic s5 s5-155u
Table of Contents

Advertisement

Applications
FB 110 continued:
Parameter
name
STAR
Start the transfer of the data block on a positive-going edge
RCPU
Receiving CPU
TNDB
Type (H byte) and number (L byte) of the data block to be
transferred.
NUMB
Number of data fields to be transferred.
FIRB
Number of the first data field to be transferred.
ERRO
Error
REST
Number of data fields still to be transferred.
1)
CUBN
Current field number
1)
EDGF
Edge flag
1)
Internal scratchpad flag, not intended for evaluation
FB 110
SEGMENT 1
0000
NAME:TRAN-DAT
DECL :STAR
I/Q/D/B/T/C: I
DECL :RCPU
I/Q/D/B/T/C: I
DECL :TNDB
I/Q/D/B/T/C: I
DECL :NUMB
I/Q/D/B/T/C: I
DECL :FIRB
I/Q/D/B/T/C: I
DECL :ERRO
I/Q/D/B/T/C: Q
DECL :REST
I/Q/D/B/T/C: Q
DECL :CUBN
I/Q/D/B/T/C: Q
DECL :EDGF
I/Q/D/B/T/C: Q
0020
:L
=RCPU
0021
:T
FY 246
0022
:L
=TNDB
0023
:T
FW 247
0024
:
10 - 62
Significance
BI/BY/W/D: BI
BI/BY/W/D: BY
BI/BY/W/D: W
BI/BY/W/D: BY
BI/BY/W/D: BY
BI/BY/W/D: BY
BI/BY/W/D: BY
BI/BY/W/D: BY
BI/BY/W/D: BI
Assign parameter field for
SF OB 202
Continued on the next page
Parameter
Data
type
type
I
BI
I
BY
I
W
I
BY
I
BY
Q
BY
Q
BY
Q
BY
Q
BI
LEN=89
CPU 948 Programming Guide
C79000-G8576-C848-04

Advertisement

Table of Contents
loading

Table of Contents