4
After switching, mount the front cover.
For how to mount, refer to [2. 2. 3].
■ With frame size A6
VFAS3-2450P, 2550P, VFAS3-4900PC to 4132KPC
1
Remove the front cover and the transparent cover inside
(transparent resin).
For how to remove, refer to [2. 2. 4].
2
Remove the screw for switching of grounding capacitor from
2
the position of the grounding mark and tighten it to the posi-
tion of the non-grounding mark.
The grounding capacitor's capacity is reduced.
3
To recover the shipping state, remove the screw(s) for
switching of grounding capacitor and tighten it/them to the
screw hole in the position of the grounding mark.
The grounding capacitor's capacity is increased.
4
After switching, mount the transparent cover and the front cover in this order.
For how to mount, refer to [2. 2. 4].
2. 3. 5
The control terminals are connected to external control equipment to control operation of the inverter
9
and motor and monitor the state externally.
■ Functions of control terminals
The control terminal block is common to all the models.
2. Installation and wiring
Control terminals
Capacity Large
Screw
Capacity
Small
2-44
E6582062