Selecting Stall Operation During Regeneration - Toshiba TOSVERT VF-AS3 Instruction Manual

Industrial inverter (for 3-phase motors)
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

6. 25. 4
<F453: Stall operation during regen>
■ Function
This function is one of the functions to prevent the lifting gear from being displaced at stop. If current
4
stall prevention gets active during regeneration of controlled stop, there may be a mismatch at stop.
Set to inhibit only the stall prevention of current.
4
■ Parameter setting
6
Title
F453
■ Selecting a setting value
To inhibit the stall prevention of current during regeneration of controlled stop, set <F453: Stall
operation during regen> to "1".
9
Reference
6. [Advanced] How to use parameters

Selecting stall operation during regeneration

Parameter name
Stall operation during
regen
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
F453 : Stall operation during regen
0: 0: Enabled
1: 1: Disabled
Adjustment range
0: Enabled
1: Disabled
6-106
E6582062
STOP
0.0Hz
13:46
Default setting
0