Toshiba TOSVERT VF-AS3 Instruction Manual page 204

Industrial inverter (for 3-phase motors)
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

Title
F560
0: Frequency only
Only the frequency command is valid.
1: With function
For each preset speed commands of 1-speed to 15-speed, direction of rotation, acceleration/
deceleration time, V/f control, and torque limit can be set.
In this case, the direction of rotation of the motor is as set with <F561: Operation function (1-speed)>
to <F576: Operation function (0-speed)>, not as the input of terminal [F] or terminal [R].
Title
4
F561 - F575
5
F576
Add the values of the functions to be used for setting. For example, when using the functions of Rev
run (+1) and Acc/Dec switching signal 1 (+2), set "3" (+1+2=+3).
9
5. [Fundamental operation] How to use parameters
Parameter name
Preset speed operation
style
Parameter name
Operation function (1-
speed) to Operation
function (15-speed)
Operation function (0-
speed)
Adjustment range
0: Frequency only
1: With function
Adjustment range
0: Fwd run
+1: Rev run
+2: Acc/Dec switching signal 1
+4: Acc/Dec switching signal 2
+8: V/f switching signal 1
+16: V/f switching signal 2
+32: Torque limit switching signal 1
+64: Torque limit switching signal 2
5-54
E6582062
Default setting
0
Default setting
0