• Select pattern groups to set the order of frequencies to operate.
 - <F522: Pattern 1 repeat number>
 - <F523: Pattern 1 select 1> to <F530: Pattern 1 select 8>
 - <F531: Pattern 2 repeat number>
 - <F532: Pattern 2 select 1> to <F539: Pattern 2 select 8>
• You can set parameter groups to operate by turning the input terminal ON/OFF.
Assign "38: Pattern operation 1" and "40: Pattern operation 2" to the two unused input
terminals.
Also, assigning "42: Pattern operation continuation" and "44: Pattern operation start" to other
input terminals allows you can select operation method by turning them ON/OFF.
6) Display status of pattern operation in [Monitor mode].
The status of the pattern operation can be checked in [Monitor mode]. Set the monitor numbers
4
shown in the following table to <F711: Monitor mode 1 display> to <F718: Monitor mode 8
display>.
4
Monitor
number
6
66
67
68
9
69

■ Pattern operation switching output

Signals can be output when all pattern operations are ended.
Assign "36: Pattern operation switching" to an output terminal.
Output is turned OFF when run command is off and when the pattern operation selection is
changed.

■ Notes for pattern operation

• You need to input pattern operation group selection from the terminal.
• When all input terminals with pattern operation assigned are turned OFF, and after pattern
operation is ended, normal operation will start.
• When multiple group numbers are simultaneously input, operations will be performed in the order
of the increasing group numbers, to automatically change to the next group. In this case, it may
take approximately 0.06 second (per pattern) to search the patterns.
• Turn pattern operation 1 or 2 ON, wait for 10 ms or more to elapse, then turn ON the run
command. Turning the run command ON early may cause operation with normal output frequency
instead of pattern operation.
• <F964: Preset speed 16> to <F979: Preset speed 31> cannot be set to pattern operation.
6. [Advanced] How to use parameters
Operation status
Pattern operation group
number
Pattern operation remaining
cycle number
Pattern operation preset
speed number
Pattern operation remaining
time
Example of
display
P1.0
Indicates Pattern group 1.
n123
Indicates that the 123rd pattern is being
performed.
F1
Indicates that 1-speed frequency is used to
operate.
123.4
Indicates that the current pattern will be ended in
123.4 seconds.