3.8

Caller ID Display

Caller ID information can be sent to the target extension in a networked system and show the Caller ID on
the phone's display. The ABB Name is also shown on LCD by searching ABB table at the target system.
Operation
A DDI call routed directly to a remote extension will send the Caller ID information to the remote system.
The DDI name set in Program 22-11-03 is also sent to the remote system.
At the remote system the Caller ID information will be displayed or, if the Caller ID number matches an
Abbreviated Dial entry the Abbreviated Dial name will be displayed.
A trunk call that is first answered and then transferred to a remote extension will display the Caller ID num-
ber and the DDI name. The Abbreviated Dial name will NOT be displayed.
Related Programs
°
20-09-02 : Class of Service Options (Incoming Call Service) - Caller ID Display
Define the option whether display Caller ID or not in each station port.
°
20-09-03 : Class of Service Options (Incoming Call Service) - Sub-Address Identification
Define whether an extension displays the Caller Sub-Address.
°
13-04 : Abbreviated Dialing Number and Name
Define the abbreviated dialing number and name. The ABB name will be shown on a phone's LCD when
the ABB table has a matching number with the incoming Caller ID. The common abbreviated number table
is used to search for a match.
SV9100 Networking Manual
Item
No.
02
Caller ID Display
Enables/disables the Caller ID display at an
extension.
Item
No.
03
Sub Address Identification
Define whether an extension displays the Caller
Sub-Address.
Item
Item
No.
01
Abbreviated Dialing Data
02
Name
Item
Item
Input Data
1-9, 0, *, #,
Pause (Press line key 1),
Recall/Flash (Press line key 2),
@ for Additional Digit for ISDN
Functionality (Press line key 3)
(max. 24 digits)
Max. 12 Characters
Default
Input
data
COS
COS 15
01-14
0-Off
1
1
1-On
Default
Input
data
COS
COS 15
01-14
0-Off
0
0
1-On
Default
No Setting
No Setting
13-25