3.2
5-38
UNIVERGE SV9100 IP K-CCIS and Electra Elite IPK II
Programming Example 2
The following example provides programming details for three systems connected
by the IP CCH for NEAX application and one system connected by legacy (T1)
K-CCIS.

Figure 5-13 Programming Example 2

Point Code 00001
Electra Elite
IPK II
System A
(1000)
UNIVERGE
SV9100
System C
(1200)
Point Code 00003
Address: 192.168.1.20
3.2.1

Chassis Programming Assignments

For this example, the following system configurations are used:
A four-digit Closed Numbering Plan using Closed Number Blocks is
used.
System A is a single-cabinet Electra Elite IPK II Expanded port
package with one B64-U20 KSU, one DTI-U( ) ETU, and a CCH(4)-U(
) ETU.
System B is a single-chassis UNIVERGE SV9100 with one CHS2U
and one GPZ-IPLE installed on the GCD-CP10 and one GCD-CCTA
blade installed.
System C is a single-cabinet UNIVERGE SV9100 port package with
one CHS2U and GPZ-IPLE Daughter Board installed on the
GCD-CP10.
2nd PVA: 192.168.1.11
T1 for K-CCIS
IP Network
(Intranet)
Issue 2.0
Point Code 00002
Address:
1st PVA: 192.168.1.10
UNIVERGE
SV9100
System B
(1100)
SV9100 IP K-CCIS