Replace the Fuse

Each GoQAM contains a power fuse. We recommend keeping spare 4.0 A, SLO BLO
250V fuses (Cisco part number 188106) for the 120/230V AC model GoQAM and
spare 6.3 A, SLO BLO 250V fuses (Cisco part number 180522) for the 48V DC model
GoQAM.
Replacing the Fuse
WARNING:
Avoid electric shock! Disconnect the power cord on this product before
you remove the fuse and only use a fuse that has the correct type and
rating.
To replace the SLO BLO 250 V fuse, follow these steps.
1
Power down the GoQAM and remove the power cord.
Locate the fuse holder on the left side of the back panel of your RF GoQAM
2
model.
Choose one of the following options:
3
For the 120/230V AC model, use a small flat-blade screwdriver to pry out the
fuse holder, then go to step 7.
For the 48V DC model, go to step 4.
4
Loosen the fuse holder by using a small flat-blade screwdriver to turn the fuse
holder counter-clockwise.
5
Remove the fuse.
6
Insert a new fuse into the fuse holder, then go to step 10.
Locate and remove the spare fuse from the hidden compartment on the fuse
7
holder.