Information About Cascaded Systems
DETAILED STEPS
Install both SCE 2000 platforms, power them up, and perform the initial system configuration. (See
Step 1
Installation and Maintenance
Configuration)
Connect both SCE 2000 platforms to the management station. (See
Step 2
Interfaces and Performing Initial System
Connect the cascade ports. The cascade ports must be connected directly in Layer 1 (dark fibers), not
Step 3
through switches. (See
Set topology configurations for each SCE 2000 platform via the connection-mode options. (See
Step 4
Information About Topology-Related
Make sure that the SCE 2000 platforms have synchronized and active SCE 2000 platform was selected.
Step 5
Use the show interface linecard 0 connection-modecommand.
If you want to start with bypass/sniffing, change the link mode to your required mode in both SCE 2000
Step 6
platforms on both links. The bypass mode will be applied only to the active SCE 2000 platform. (See
How to Set the Link
Make sure that the link mode is as you required. (See
Step 7
Use the show interface linecard 0 link modecommand.
Connect the traffic port of SCE 2000 platform #1. This will cause a momentary down time until the
Step 8
network elements from both sides of the SCE 2000 platform auto-negotiate with it and start working
(when working inline). (See
Connect the traffic port of SCE 2000 platform #2. This will cause a momentary down time until the
Step 9
network elements from both sides of the SCE 2000 platform auto-negotiate with it and start working
(when working inline). (See
When full control is needed, change the link mode on both SCE 2000 platforms on both links to
Step 10
'forwarding'. It is recommended to first configure the active SCE 2000 platform and then the standby.
(See
You can now start working with the Subscriber Manager.
Step 11

CLI Commands for Cascaded Systems

This section presents CLI commands relevant to the configuration and monitoring of a redundant system.
Use the following commands to configure and monitor a redundant system:

Topology-Related Parameters for Redundant Topologies

All four of the topology-related parameters are required when configuring a redundant topology.
Cisco SCE 2000 4xGBE Installation and Configuration Guide
6-12
and
Dual Link: Two SCE 2000s
Mode.)
Dual Link: Two SCE 2000s
Dual Link: Two SCE 2000s
How to Set the Link
Mode.)
connection-mode
[no] force failure-condition
Show interface linecard 'number' connection-mode
Show interface linecard 'number' physically-connected links
Chapter 6
Cabling the Line Ports and Completing the Installation
Connecting the Management Interfaces and Performing Initial System
Configuration.)
Topology.)
Parameters.)
Monitoring the
Topology.)
Topology.)
Connecting the Management
System.)