Troubleshooting Overview
GBE link is up but not receiving from peer (GBE link is lit, but Rx LED is not flashing)
Table 8-7
Symptom
Link is down.
(LINK LED not lit)
Status is
WARNING (Status
LED is flashing
orange)
Output counters not
incrementing.
GBE link is up
(GBE interface link
LED is continuous
green and GBE
interface Tx LED is
flashing)
Peer does not
receive traffic from
SCE 2000
Cisco SCE 2000 4xGBE Installation and Configuration Guide
8-12
Troubleshooting the Link Interface Subsystem
Diagnostic Action
CLI command:
show interface
GigabitEthernet
0/# counters
CLI commands:
show interface
GigabitEthernet 0/#
counters
Check output of this
command for: "In good
unicast packet" and
"Out unicast packet".
These counters should
be constantly
incrementing.
CLI commands:
show interface
GigabitEthernet
0/# counters
Check output of this
command for: "Out
unicast packet". This
counter should be
constantly
incrementing.
show interface
GigabitEthernet 0/#
Possible Cause
Possible Solution
Connector is not
Reconnect the cable to
connected to the
the GBE port and to
platform or to the
network.
network.
GBE cable is broken.
Reconnect / replace the
cable to the GBE port.
If GBE counters are
incrementing, this
indicates LED problem.
Contact customer
support.
Auto-negotiation may
Check
be incorrectly
Ports and Completing
configured.
the
Installation
on in the SCE 2000 and
in peer.
Auto-negotiation is
Check configuration in
disabled at the SCE
the SCE 2000 and in
2000 but enabled at
peer.
peer.
Chapter 8
Troubleshooting
Cabling the Line
configurati