Remote Network Monitoring (Rmon) Commands - D-Link DXS-3600-16S Manual

Dxs-3600 series layer 2/3 managed 10gbe switch
Hide thumbs Also See for DXS-3600-16S:
Table of Contents

Advertisement

Remote Network MONitoring (RMON) Commands

51-1 rmon collection stats
This command is used to add a statistic entry. Use the no form of this command to remove a statistic entry.
rmon collection stats index [owner ownername]
no rmon collection stats index
Parameters
index
owner ownername
Default
Command Mode
Command Default Level
Usage Guideline
Example
DXS-3600-32S#configure terminal
DXS-3600-32S(config)#interface tenGigabitEthernet 1/0/1
DXS-3600-32S(config-if)#rmon collection stats 100
DXS-3600-32S(config-if)#
Example
DXS-3600-32S#configure terminal
DXS-3600-32S(config)#interface tenGigabitEthernet 1/0/1
DXS-3600-32S(config-if)#no rmon collection stats 100
DXS-3600-32S(config-if)#
51-2 rmon collection history
This command is used to add a history entry. Use the no form of this command to remove a history entry.
rmon collection history index [owner ownername] [buckets bucket-number] [interval seconds]
no rmon collection history index
Parameters
index
owner ownername
buckets bucket-number
interval seconds
DXS-3600 Series 10GbE Layer 2/3 Switch CLI Reference Guide
Specifies the statistic index in the range of 1 to 65535.
Specifies the string that describes the owner name information. The maximum length
is 127 characters (please refer to the RFC1213 for more information about the
maximum length parameter).
None.
Interface Configuration Mode.
Level: 12
At the present, this switch supports only the statistics of the Ethernet interface. Add
an RMON collection statistic for the specified interface on the switch.
This example shows how to add a statistic entry.
This example shows how to remove a statistic entry.
Specifies the history index in the range of 1 to 65535.
Specifies the string that describes the owner name information. The maximum length
is 127 characters (please refer to RFC1213 for the maximum length in detail).
Specifies the used data source and time interval. Each sampling interval should be
sampled once. The sampling results are saved. The bucket-number specifies the
maximum number of sampling. When the maximum is reached for the sampling
records, the new one will overwrite the earliest one. The value range of Bucket-
number is 1 to 65535. Its default value is 50.
Specifies the sampling interval in the range of 1 to 3600 seconds, 1800 seconds by
default.