Alarm Data Parameters
Parameter
ICIM
Name (LCI)
Abbrev.
RF
InRF
Input
Power *
Optical
OutPwr
Output
Power *
Laser
LasTemp
Temperature *
Laser
LasBias
Bias
Current *
Laser
Enable
Enable
Status
Power
PsOk
Supply
Status
* Alarm limit values for this parameter are relative to the nominal alarm value.
78-4019959-01 Rev D
Nominal
Major
Value
Low
Limit
0.0 dB
-9.0
dB
10.1 dBm
-1.0
dBm
19.9°C
-15.0°C
88.8 mA
-20.0
mA
-
-
-
-
High Density SuperQAM Transmitter Parameters
Minor
Minor
Major
Low
High
High
Limit
Limit
Limit
-5.0
5.0
7.5
dB
dB
dB
-0.5
0.5
1.0
dBm
dBm
dBm
-5.0°C
5.0°C
15.0°C
-10.0
10.0
20.0
mA
mA
mA
-
-
-
-
-
-
Hys-
Operating
teresis
Range
1.0
-4.5 dB to
+3.0 dB
0.1
±0.5 dB of
nominal
1.0
20°C to
30°C
0.001
50 mA to
100 mA
-
OK or
Fault
-
OK or
Fault
107