AQ25A SERIES PROGRAMMABLE BOILER CONTROL PANELS
Menu Option
A/C EQUIP CONFIG
Central A/C – Available only if no AQ158 controller is present on the network.
ZONE
A-1 to D-16
A/C UNIT
NONE / 1
COOLING
ENABLE / DISABLE
STATISTICS
Displays the summary and Zone relay activity (hours of operation or cycles since last reset)
LAST DATA
Max. 24,855 days (68 years)
RESET
RESET ALL DATA
YES / NO
ARE YOU SURE?
BOILER FIRE
Maximum of 596,523 hours
ACTIV
(68 years)
BOILER PUMP
Maximum of 596,523 hours
ACTIV
(68 years)
DHW PUMP
Maximum of 596,523 hours
ACTIV
(68 years)
AUX PUMP
Maximum of 596,523 hours
ACTIV
(68 years)
AUX OUT
Maximum of 596,523 hours
ACTIV
(68 years)
ZONE A-1
Maximum of 596,523 hours
ACTIV
(68 years)
ENVIRACOM
Not used - reserved for future use.
Modules ID:
n/a
SAVE / RESTORE
Options for saving settings or restoring previously-saved settings
RESTORE
n/a
FACTORY
RESTORE
n/a
SETUP
SAVE SETUP
n/a
69-2119—02
Table 6. Installer Menu – Equipment Setup. (Continued)
EQUIPMENT SETUP
Factory
Range
Default
A-1
1
ENABLE
2000 JAN 01 Date of last reset formatted as YYYY MMM DD.
NO
0H
0H
0H
0H
0H
0H
n/a
n/a
n/a
n/a
34
Description
Selects the desired zone.
Defines which A/C compressor is associated with each
zone thermostat.
NOTE: At this time, only one zone of A/C can be handled
by the AQ2000 controls. The options are 1 (if the
zone uses an AQ1000TP2 programmable
thermostat and can call for cooling), or NONE.
Enables or disables the cooling functions of the zone's
programmable thermostat (AQ1000TP2).
NOTE: This item is always set to DISABLE when a non-
programmable thermostat (AQ1000TN2) is used
in the selected zone.
Selecting YES resets all of the summary and zone activity
values to zero.
Hours of operation of the relay since last reset.
Hours of operation of the relay since last reset.
Hours of operation of the relay since last reset.
Hours of operation of the relay since last reset.
Hours of operation of the relay since last reset.
Hours of operation of the zone's relay (e.g., zone A-1)
since last reset.
The zone Identifier is A-1 through D-16.
Selecting this option restores all settings to their factory
defaults
Selecting this option restores all settings to those saved by
the Installer with the SAVE SETUP operation. RESTORE
SETUP is only displayed as a menu option if installer
settings have previously been saved using the SAVE
SETUP menu option.
Only displays if the installer has previously saved his (non-
factory default) settings using the SAVE SETUP feature.
Enables installer to SAVE system settings once the system
has been set up and is working well; Designed to facilitate
quick recovery to proper system operation in the event of
inadvertently changing control settings (e.g., tampering
with the system settings by an inexperienced user).
n/a