Control Panel Mounting
LOCATION
Mount the AQ251, AQ25A or AQ252 panel as close as
possible to the connected hydronic system components
(boiler, DHW tank, circulators, etc.) to minimize the length of
wiring between these components and the AQ Control Panel.
The location should be:
• Less than 90% relative humidity, non-condensing
• Between 32° and 125° F (0° to 50° C)
• On an interior wall in a well-ventilated area
• Easily accessible for installation of wires, programming of
the control, and maintenance / diagnostics after installation
(preferably at eye level)
• Free of the possibility of water leakage or spray into the
control
• A sturdy structure such as a stud framed wall, a plywood
panel or separate electrical panel.
MOUNTING TEMPLATE
USE OF INSTALLATION TEMPLATE
1. Using masking tape, attach the mounting template to
the vertical surface where the panel is to be installed.
Ensure that the template is level before proceeding.
2. Using a sharp pencil, mark the location of the four
mounting screws indicated on the template. Push
sufficiently hard so the pencil cuts through the template
and marks the wall in all four mounting locations.
3. Remove the template from the wall and set aside.
4. Drill holes large enough to accommodate No. 8 or 10
screws and mounting plugs (not included).
5. Once the plugs are placed in the wall, insert the top two
screws until they are extending about 0.5 in. (12.7 mm)
out from the wall.
6. Carefully hang the control panel on the top two screws
and check that the bottom two mounting holes align with
the bottom two plugs already in the wall.
7. Insert the bottom two screws and screw them in
completely so they are snug. Do not overtighten the
screws, or the panel's plastic housing may be
damaged.
8. Complete the mounting by securing the top two screws
until they are also snug.
69-1976-03

Advertisement

loading

Summary of Contents for Honeywell AQ25142B

  • Page 1 AQ25142B, AQ25144B, AQ25242B OR AQ25244B CONTROL PANEL MOUNTING AQ25142B, AQ25144B, AQ25A42B, AQ25A44B, AQ25242B or AQ25244B Control Panel Mounting MOUNTING TEMPLATE LOCATION USE OF INSTALLATION TEMPLATE Mount the AQ251, AQ25A or AQ252 panel as close as 1. Using masking tape, attach the mounting template to possible to the connected hydronic system components the vertical surface where the panel is to be installed.
  • Page 2 AAAQ25142B / AQ25144B / AQ25A42B / AQ25A44B / AQ25242B / AQ25244B 3/16 (5) x (2) 5/16 (8) THIS TEMPLATE MAY BE USED FOR INSTALLING AN AQ25142B, AQ25144B, AQ25A42B, AQ25A44B, 5-7/8 (149) AQ25242B OR AQ25244B CONTROL PANEL. DIMENSIONS IN INCHES (MM).

This manual is also suitable for:

Aq25144bAq25a42bAq25a44bAq25242bAq25244b