LCD Display Navigation
This section describes how the keypad is used to navigate the
LCD display and menus.
• The LCD displays up to three lines of text at a time. For
menus with more than three lines, use the up and down
buttons (
or v) to scroll through the menu options.
^
• As the menu is scrolled up or down, the indicator arrow (←)
shows which menu item is active.
• If the active menu item is part of a list of predefined options
(e.g., Day of the Week) press the – or + button to scroll
through the available options until the preferred option is
displayed. The option is automatically saved when the
indicator arrow is scrolled away from the value being edited.
• If the active menu item requires you to define a value (e.g.,
a setpoint), use the – or + button to decrease or increase
the value until the desired value is displayed. The selection
will be saved when the indicator arrow is scrolled up or
down.
NOTES:
1.
When setting times for the setback schedule, you
must use the – or + button to change the time.
2.
The OK button, when pressed, defaults the time
setting to "--:--" (midnight).
• If the active menu item leads to a further sub-menu,
pressing the OK button displays the sub-menu options on
the LCD. Scroll through this sub-menu to position the
indicator arrow (←) beside the desired menu item to input or
modify. Choose one of the options provided or input the
desired value for the menu item. When satisfied, scroll to
another item and your selection will be saved.
• To define or modify another item within the same menu,
scroll the up and down buttons (
arrow (←) is beside the desired option. Use the – or +
buttons to set the value for that item.
• To move back (up) one level within a menu, press the Menu
button.
• To return to the Home Page display, press the Home button.
NOTE: The AQ25A automatically returns to the Home Page
display after 60 minutes of inactivity on the keypad.
HOME PAGE DISPLAY
The Home Page is the default view displayed on the AQ25A
Control Panel's LCD screen.
There are two Home Page views - Simple and Detail.
• Simple view shows 3 lines of text and is a brief description
of the system operation: Day, Time of Day, Current Program
and Outdoor temperature.
• Detail view includes the same 3 lines plus up to 10 lines of
additional information, including Boiler Supply and Return
temperatures, Secondary (Mixed loop) temperature, Boiler
Supply Target temperature, Secondary Loop Target
temperature, Zone Count, and DHW temperature (if
configured for DHW sensor use). Detail view is the factory
default setting for the Home Page.
The choice of the Simple or Detail Home Page view is made
from the USER MENU > PREFERENCES/TIME menu option.
The Home Page together with the System Status information
(a selection from the User Menu), provide a service contractor
extensive diagnostic information for troubleshooting the
installation.
or v) until the indicator
^
17
AQ25A SERIES PROGRAMMABLE BOILER CONTROL PANELS
NOTES: Home Page display upon restart after a power failure
of more than four hours:
1.
Upon restarting the AQ25A following a power dis-
ruption of greater than 4 hours, the message PLS
SET DAY/TIME OF DAY displays on the top line of
the Home Page screen. The message disappears
after the DAY and TIME OF DAY are updated.
— If the power failure parameter is set to Back-
light (USER MENU > PREFERENCES), the
LCD backlight flashes repeatedly, along with
the message.
2.
The AQ25A starts up with its clock settings as:
DAY = MONDAY, TIME OF DAY = 12:00 midnight,
and program = OCCupied.
3.
Until the DAY and TIME OF DAY settings are
adjusted, the control remains in permanent
setpoint (comfort) mode.
4.
When the DAY and TIME OF DAY settings are
adjusted, the AQ25A follows the four programs of
WAKE, LEAVE, RETRN (return), and SLEEP.
Refer to "Home Page" on page 23 in the "Appendix" for
illustrations of the Simple and Detail displays.
Programming the AQ25A
Program the AQ25A by using the keypad and LCD display to
select parameters from the User and Installer menus. Refer to
to Fig. 22 on page 16 for an illustration of the LCD screen and
keypad.
NOTE: The figures in "Menu Structure" on page 37 provide a
graphical layout of the AQ25A's User and Installer
menus.
When a new AQ2000 component is connected on the
AQUATROL network, it is seamlessly integrated in the system
after a few seconds. If one or more components are
disconnected or stop providing data to the network, a message
will appear on the System Status display until the fault is
corrected.
User Menu
The User Menu is intended for use by the building owner to
choose the LCD display preferences, Zone Settings (including
setpoint temperatures and setback times for each zone), and
temperatures for the WAKE, LEAVE, RETRN (return), and
SLEEP programs.
The Home Page and User Menu allow the building owner to:
• View the status of the system.
• Set up preferences for how the system information is
displayed.
• Set target temperatures for each zone.
• Program times of the day when the system will set back the
temperatures for all zones.
NOTE: If there are any problems with the system's operation,
the AQ25A displays error codes on the System Status
Page display of the LCD panel. For details on these,
refer to "Troubleshooting" on page 20.
TO ACCESS THE USER MENU:
Press the Menu button on the keypad at any time to access the
User Menu.
69-2119—02