CHAPTER
19
Instrument Specifications
Size
Weight
Gas Sensor Slots
Battery
Display
Display Readout
Keypad
Gas Sampling Method
Calibration
Alarms
Datalogging
Location
RF Power
IP Rating
Operating Temperature
Humidity
Safety Certifications
BW RigRat

Specifications

15.75" x 11.4" x 18.5" (400 x 290 x 470 mm)
17.7 lbs (8 kg)
Up to 6
Rechargeable Li-ion battery, 3.7V/26.4Ah
Note: All battery specifications at 20° C; lower temperatures might
affect runtime.
3.5" 240 x 320 TFT color LCD with white LED backlight
• Real-time reading of gas concentrations; battery status;
datalogging on/off; wireless on/off and wireless reception quality.
• STEL, TWA, peak, and minimum values
• Policy enforcement indicator
• GPS quality indicator (if GPS equipped)
1 pushbutton for operation and programming
Pumped (typical flow rate of 450cc/min) or Diffusion
Device Configurator mobile application, or manual
• Red/Yellow/Green bright LED alarm
• Buzzer alarm 108dBA @1m
• On-screen indication of alarm conditions
• Gas sensors and GPS data at one minute internal for 4 months
• Datalogging interval setting: 1 to 3600 sec (default: 1 min)
Outdoor, GPS, 10m accuracy, Optional
Up to 4dBm/2.5mW(BLE); up to 17dBm/50mW (Mesh); up to
11dBm/12.5mW (Wi-Fi)
IP65 for Pumped; IP67 for Diffusion.
-20°C to +60°C (-4°F to 140° F) for Pumped; -40°C to +60°C (-
40°F to 140° F) for Diffusion, depending on sensor specification.
5% to 95% RH Non-Condensing
IEC Ex No: IECEx NEP 20.0003X
Ex ia IIC/IIB T4; Ga Ex da ia IIC/IIB T4; Ga Ex db ia IIC/IIB T4 Gb
ATEX No: SEV 20 ATEX 0389 X
II 1G Ex ia Ⅱ C/Ⅱ B T4 G; II 1G Ex da ia Ⅱ C/Ⅱ B T4 Ga; II 2G Ex db ia
99