Honeywell BW RigRat User Manual page 52

Local area gas monitor
Hide thumbs Also See for BW RigRat:
Table of Contents

Advertisement

Extension cable (W03-2168-000)
W03-2168-000 IS barrier to BW RigRat cable, 100meters, with 3-pin connector.
Total 100m cable IS parameters: (C=80pF/m; L=0.7uH/m; R=23.2mΩ /m)
Ct=8nF
Lt=0.07mH
BW RigRat IS parameters in hazardous area:
Ui=24V
Ii= 150 mA
Pi=1.15W
Ci=0.36nF.
Li=0uH
For hazardous applications, these conditions must be met:
Uo ≤ Ui
Io ≤ Ii
Po ≤ Pi
Co ≥ Ci + Ct
Lo ≥ Li + Lt
Uo/Io/Po/Co/Lo are IS barrier output parameters
Ui/Ii/Pi/Ci/Li are RigRat input parameters
Ct/Lt are extension cable additional parameters
+
IS barrier output, positive
-
IS barrier output, negative
NC
Not connect
BW RigRat
51
User Manual

Advertisement

Table of Contents
loading