Honeywell BK V2 Operating Instructions Manual

White meters, component of a diaphragm gas meter

Advertisement

Quick Links

03251309
1000243906-002-04
www.docuthek.com
D
GB
I
 

Operating instructions

White meters
BK V to BK V
(component of a diaphragm gas
meter)
Contents
Contents
White meters BK V to BK V
(component of a diaphragm gas meter) . . . . 
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
White meters BK V2 to BK V12 . . . . . . . . . . . . . 2
Type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2
Type label/Marking . . . . . . . . . . . . . . . . . . . . . . . 2
sensor (optional) . . . . . . . . . . . . . . . . . . . . . . . 
Integrated valve (optional). . . . . . . . . . . . . . . . 
Connecting the piping . . . . . . . . . . . . . . . . . . . . 4
Pressure test point on outlet connector
(optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Opening the test nipple . . . . . . . . . . . . . . . . . . . 5
Closing the test nipple . . . . . . . . . . . . . . . . . . . . 5
Tightness test . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 5
Maintenance/Removal. . . . . . . . . . . . . . . . . . . 5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 6
Declaration of conformity . . . . . . . . . . . . . . . . 7
protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
protection and integrated valve Ve . . . . . . . . . . . 8
ATEX legend . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Safety
Safety
Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
• ,  ,  ,  ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Changes to edition 0.6
The following chapters have been changed:
-
Checking the usage
-
Integrated valve
-
Technical data
-
Declaration of conformity
GB-1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell BK V2

  • Page 1: Table Of Contents

    Checking the usage .....  Indicates possible material damage. White meters BK V2 to BK V12 ... . . 2 All interventions may only be carried out by qualified Type code .
  • Page 2: Checking The Usage

    Part designations Checking the usage White meters BK V to BK V White meters are components of diaphragm gas meters and cannot be operated independently. They are suitable for recording gas consumption values for natural gas, town gas, propane and butane, as gases of the first to third families pursuant to DIN EN 437:2003 (DVGW Code of Practice G260), and can be extended to form complete diaphragm...
  • Page 3: Integrated Pressure And Temperature

    White meters with integrated valve Ve from the operating instructions for the control – CE marking and ATEX identification electronics. ▷ Technical data, see page 6 (Technical data). II 3 G IIB T4 17 ATEX 1431X Installation – Valve marking Ve = bi-stable valve for electronic flow rate WARNING testing ATEX-compliant use is as follows:...
  • Page 4: Pressure Test Point On Housing (Optional)

    ▷ If the meter is stored outdoors, protect the site Pressure test point on housing against rain. (optional) ▷ If the drive area (magnetic coupling) is protected against the ingress of moisture by an index, then the meter is also suitable for outdoor installation. ...
  • Page 5: Opening The Test Nipple

    ▷ When reinstalling, the union nut will be turned to ▷ If a pressure measuring line has been retrofitted the original position and then further tightened to the meter, check this connection for tightness. through approx. 30°. 0 Once the installation and tightness test are com- plete, see page 5 (Tightness test), protect the pressure test point against external access with the sealing sleeve and the seal.
  • Page 6: Technical Data

    – Max. allowable gas temperature range * = -25°C to +55°C – Cyclic volume V BK V2, BK V2S: V = 2 dm³ BK V6: V = 6 dm³ BK V12: V = 12 dm³ – Transitional flow rate Q = 0.1 x Q...
  • Page 7: Declaration Of Conformity

    Declaration of conformity Scan of the Declarations of conformity – see www.docuthek.com → Elster-Instromet White meters BK V – V with explosion protection GB-7...
  • Page 8: White Meters Bk V2 With Explosion Protection And Integrated Valve Ve

    White meters BK V with explosion protection and integrated valve Ve GB-8...
  • Page 9: Atex Legend

    ATEX legend = Marking of explosion protection II = Equipment group ll for general industries (with the exception of mines) -/2 = Category: internal: none external: Category 2 (Zone 1) 3 = Category 3 (Zone 2) G = Type of atmosphere: gases, hazes and vapours c = “Constructional safety”...
  • Page 10: Contact

    Contact Contact United Kingdom Elster Metering Limited Paton Drive Tollgate Business Park Beaconside Stafford, ST16 3EF T +44 1785 275200 F +44 1785 275305 jeavons.info@gb.elster.com www.elstermetering.co.uk Ireland Germany Active Energy Control Ltd. Elster GmbH Unit 4, Clare Marts Strotheweg 1 Quin Road 49504 Lotte Ennis, Co.

This manual is also suitable for:

Bk v12

Table of Contents