5.3.6. Vertical Microactivity

Selectable from 0 to 31. This setting is used to reduce the effects
of lost motion in the system. Cable operated systems will need to use
a higher value. Most pushrod control systems can use a value of 0.
Obtain factory assistance before making large adjustments to this
setting. The vertical axis PMICRO ACT setup screen is shown in
Figure 5.3.6a.

5.3.7. Half Step

Selectable between 0 and 1. This setting is used to tune out an
almost imperceptible pitch oscillation where one step of the servo is
too much adjustment. Set to 1 to enable. The HALF STEP setup
screen is shown in Figure 5.3.7a.