Faults
Message
I1 Warn. sig.
I2 Warn. sig.
I3 Warn. sig.
I4 Warn. sig.
Batt. low
c) Remarks:
Clock n. set
Encoder err.
CDL full
U.Logb. full
online
I1-Rep. sig.
I2-Rep. sig.
I3-Rep. sig.
I4-Rep. sig.
Description, process
When an input is configured as a warning input, if an
active signal is present on the relevant terminal (i.e.
terminal DI2) this message is displayed.
The input configurations can be changed using the pa-
rameterization program "enSuite".
The remaining battery service life is less than 6 months.
The batteries must be replaced soon.
Calibration of the volume corrector's internal clock has
not yet been carried out by the factory.
On the encoder connected to input 1 or input 2 no meter
reading could be detected for 20 seconds (with external
voltage supply) or for the duration of an encoder readout
cycle "
" (with battery power supply).
EZyk
The Certification Data Log is full. A change to "PL"
identified access parameters without calibration lock is
not possible, until the contents of the Certification Data
Log are cleared.
The software Update Log is full. An update is not possi-
ble until the contents of the software update log are
cleared.
Data is currently being transmitted via an interface
(modem or optical interface).
If this message is displayed, the "o" will flash in the "Sta-
tus" field of the display (see chapter 6.3.4, page 58).
When an input is configured as a remark input, if an
active signal is present on the relevant terminal (i.e.
terminal DI2) this message is displayed.
The input configurations can be changed using the
parameterization program "enSuite".