Assembly, Connection and Putting into Operation
–
On successful detection the DL230 displays the label "Vo1" on the me-
ter reading of the meter:
Serv. Input 1 Vo1
Unlike the "Auto Detect" function, you can also select the connected
encoder type directly under "Md.I1".
Serv. Input 1 Parameter settings Md.I1
The following encoder types can be selected:
Md.E1
Enc.Namur a
Enc.SCR EDIS
Enc.SCR OBIS
Enc.SCR+EDIS
Enc.SCR+OBIS
Enc.Nam. a-b
The same process can be used for input 2.
With the parameter "
tervals the encoder is read out. Default is 900 seconds (15 minutes).
Changing this parameter has a significant impact on battery life !
"EZyk" can be found in the display under the path:
Serv.
Device settings
5.3.1.4 Adjusting meter readings
To control the measuring of volumes, the meters (V1 to V4) of the DL230
can be adjusted to the same respective value as the meters connected
when the calibration or administrator lock is open (with an entry in the PTB
log).
–
Open the calibration lock or the administration lock
–
Move the cursor to the "Serv." register and to the value "V1", "V2", "V3"
or "V4":
Serv. Input 1 V1
Serv. Input 2 V2
Serv. Input 3 V3
Serv. Input 4 V4
Press the ENTER button. One of the value's digits flashes.
–
Move the cursor to the digits using the or arrow keys and update
–
them using the or arrow keys.
Description
Encoder with Namur a protocol
Encoder SCR with EDIS95 protocol
Encoder SCR with OBIS05 protocol
Encoder SCR+ with EDIS95 protocol
Encoder SCR+ with OBIS05 protocol
Encoder with Namur a and b protocols
EZyk
" you can set for both encoder inputs at what in-
Measurement
45