Cisco Catalyst 6500 Series Installation Manual page 36

Switch module
Hide thumbs Also See for Catalyst 6500 Series:
Table of Contents

Advertisement

Supervisor Engines
LEDs
Table 1-3
Supervisor Engine LEDs
LED
Color/State Description
STATUS
Green
Orange
Red
1
SYSTEM
Green
Orange
Red
ACTIVE
Green
Orange
1
PWR MGMT
Green
Orange
Catalyst 6500 Series Switch Module Installation Guide
1-12
The LEDs on the supervisor engine front panel indicate the status of the
supervisor engine, modules, power supplies, and the fan assembly.
the LEDs and their function.
All diagnostics pass. The module is operational (normal initialization
sequence).
The module is booting or running diagnostics (normal initialization
sequence).
An overtemperature condition has occurred. (A minor temperature
threshold has been exceeded during environmental monitoring.)
The diagnostic test failed. The module is not operational because a fault
occurred during the initialization sequence.
An overtemperature condition has occurred. (A major temperature
threshold has been exceeded during environmental monitoring.)
All chassis environmental monitors are reporting OK.
The power supply has failed or the power supply fan has failed.
Incompatible power supplies are installed.
The redundant clock has failed.
2
One VTT
module has failed or the VTT module temperature minor
threshold has been exceeded
Two VTT modules fail or the VTT module temperature major threshold
has been exceeded
The temperature of the supervisor engine major threshold has been
exceeded.
The supervisor engine is operational and active.
The supervisor engine is in standby mode.
Sufficient power is available for all modules.
Sufficient power is not available for all modules.
3
.
3
.
Chapter 1
Product Overview
Table 1-3
lists
78-15725-02

Hide quick links:

Advertisement

Table of Contents
loading