Download Print this page
Cisco Catalyst 6500 Series Installation Note
Cisco Catalyst 6500 Series Installation Note

Cisco Catalyst 6500 Series Installation Note

Distributed forwarding card 4 for ws-x68xx, ws-x69xx, and select ws-x67xx modules
Hide thumbs Also See for Catalyst 6500 Series:

Advertisement

Quick Links

Catalyst 6500 Series Distributed Forwarding
Card 4 for WS-X68xx, WS-X69xx, and Select
WS-X67xx Modules Installation Note
Revised: January 2014
Product numbers:
WS-F6K-DFC4-A(=)
WS-F6K-DFC4-E(=)
This publication contains the procedures for installing and removing the Distributed Forwarding Card 4
(DFC4) daughter card on the WS-X67xx Ethernet modules that support the DFC4.
Note
Throughout this publication, unless otherwise noted, the term DFC4 daughter card refers to the DFC4-A,
DFC4-AXL, DFC4-E, and DFC4-EXL daughter cards.
Contents
This publication contains these sections:
Americas Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
WS-F6K-DFC4-AXL(=)
WS-F6K-DFC4-EXL(=)
Overview, page 2

Advertisement

loading

Summary of Contents for Cisco Catalyst 6500 Series

  • Page 1: Table Of Contents

    • Removing a CFC or DFC3 Daughter Card, page 10 Removing a DFC4 Daughter Card, page 18 • Installing a DFC4 Daughter Card, page 23 • Americas Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA...
  • Page 2: Overview

    WS-X6848-SFP-2T) WS-F6K-DFC4-AXL (Module is labeled WS-X6848-SFP-2TXL) WS-X6848-GE-TX WS-F6K-DFC4-A (module is labeled The WS-X6848-TX module cannot be upgraded. WS-X6848-TX-2T) WS-F6K-DFC4-AXL (module is labeled WS-X6848-TX-2TXL) Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 3: Required Tools And Parts

    Your own ESD-prevention equipment or the disposable grounding wrist strap included in the • upgrade kit Number 1 Phillips-head screwdriver for the DFC daughter card installation hardware • Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 4: Safety Overview

    à la fin de chaque avertissement. CONSERVEZ CES INFORMATIONS Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 5 Al final de cada advertencia encontrará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo. GUARDE ESTAS INSTRUCCIONES Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 6 Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 7 Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 8 Safety Overview Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 9 Statement 1030 Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Statement 1034 Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 10: Removing A Cfc Or Dfc3 Daughter Card

    “Removing and Installing Ethernet Modules in the Chassis” section on page 28 for removal instructions. Place the Ethernet module on an antistatic mat with the front of the module facing toward you. Step 3 Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 11 Do not reinstall the stiffener bracket. After upgrading the WS-X6748-GE-TX Ethernet module with a Caution DFC4 daughter card, the bracket can be discarded. Figure 1 WS-X6748-GE-TX Ethernet Module Equipped with a Stiffener Bracket Stiffener bracket WS-X5530 Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 12 Figure Figure 2 CFC Daughter Card Installation Hardware Cap nuts (2) Card removal tabs (2) CFC daughter card Heat sinks Screws (3) WS-X5530 Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 13 CFC daughter card in an antistatic bag. Proceed to the “Installing a DFC4 Daughter Card” section on page Step 8 Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 14 DFC3B or DFC3BXL daughter card. The Note installation hardware for a DFC3C or a DFC3CXL daughter card consists of 6 screws, 2 cap nuts, and 1 standoff. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 15 DFC3 daughter card does not move horizontally and cause damage to the base board. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 16 DFC3 daughter card up and down with your right hand, no more than half an inch in either direction, to unseat the DFC3 daughter card from the module. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 17 Holding the DFC3 daughter card with both hands, gently lift it straight up from the module. (See Step 10 Figure 7.) Immediately place the DFC3 daughter card in an antistatic bag. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 18: Removing A Dfc4 Daughter Card

    WS-F6K-DFC4-E Step 4 or WS-F6K-EXL daughter card mounting hardware. See Figure 9 for removing the WS-F6K-DFC4-A or WS-F6K-DFC4-AXL daughter card mounting hardware. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 19 Removing DFC4 Daughter Card Installation Hardware (WS-F6K-DFC4-A or -AXL) Installation bracket. May or may not be present. WS-X5530 Figure 9 Removing DFC4 Daughter Card Installation Hardware (WS-F6K-DFC4-E or -EXL) Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 20 DFC4 daughter card up and down with your right hand, no more than half an inch in either direction, to unseat the DFC4 daughter card from the module. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 21 Holding the DFC4 daughter card with both hands, gently lift it straight up from the module. (See Step 8 Figure 12.) Immediately place the DFC4 daughter card on an antistatic mat or in an antistatic bag. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 22 Removing a DFC4 Daughter Card Figure 12 Removing the DFC4 Daughter Card from the Module Unseat the DFC power connector Lift here Lift here WS-X5530 Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 23: Installing A Dfc4 Daughter Card

    Figure 13 Mounting Holes on the DFC4 Daughter Card Align with the male standoffs on the module Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 24 Ensure that the connectors on the DFC4 daughter card are aligned with the connectors on the module. Apply pressure to the area shown in Figure 15 to seat the power connector. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 25 If you exert pressure on the heat sinks, they can break off of the components they are attached to. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 26 You should visually verify that there are standoffs beneath the mounting holes before installing Note the installation hardware. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 27 Installing the Mounting Hardware for a DFC4-A and DFC4-AXL Daughter Card WS-X5530 Figure 18 Installing the Mounting Hardware for a DFC4-E and DFC4-EXL Daughter Card Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 28 Removing and Installing Ethernet Modules in the Chassis This section describes how to correctly remove and install an Ethernet module in a Catalyst 6500 series switch chassis slot. The WS-X68xx and the WS-X69xx Ethernet modules require that adjacent slots (above and below or to...
  • Page 29 Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 30 If the STATUS LED remains orange or turns red, the module has not successfully completed the boot process and may have encountered an error. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 31 INPUT OUTPU T FAIL INPUT OUTPU T FAIL WS -X67 48-G E-T X 48 POR T ETH ERN ET Ejector lever fully extended Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 32 EMI gasket and the module above it Figure 21 Ejector Lever Closure in a Horizontal Slot Chassis Ejector levers flush with module faceplate Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 33 If the STATUS LED remains orange or turns red, the module has not successfully completed the boot process and may have encountered an error. Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 34 Positioning the Module in a Vertical Slot Chassis Ejector lever fully extended STATUS gasket gasket INPUT OUTPUT FAIL INPUT OUTPUT FAIL Insert module between slot guides Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 35 Gap between the module EMI gasket and the module above it 1 mm STATUS Press left Press left INPUT OUTPUT FAIL INPUT OUTPUT FAIL Catalyst 6500 Series Distributed Forwarding Card 4 for WS-X68xx, WS-X69xx, and Select WS-X67xx Modules Installation Note OL-24918-02...
  • Page 36 Cisco currently supports RSS Version 2.0. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners.