Figure 14-4. Format of Automatic Data Transmit/Receive Control Register
Symbol
<7>
<6>
<5>
ADTC
RE
ARLD ERCE ERR
Notes 1. Bits 3 and 4 (TRF and ERR) are read-only bits.
2. The termination of automatic transmission/reception should be judged by using TRF, not
CSIIF1 (interrupt request flag).
Caution When external clock input is selected with bit 1 (CSIM11) of serial operating mode
register 1 (CSIM1) set to 0, set STRB and BUSY1 of ADTC to 0, 0.
Remark ×: don't care
264
CHAPTER 14 SERIAL INTERFACE CHANNEL 1
<4>
<3>
<2>
<1>
<0>
TRF STRB
BUSY1 BUSY0
R/W
R/W
R/W
R/W
R/W
User's Manual U11302EJ4V0UM
Address
After reset
FF69H
00H
BUSY1
BUSY0
Busy input control
×
0
Not using busy input
1
0
Busy input enabled (active high)
1
1
Busy input enabled (active low)
STRB
Strobe output control
0
Strobe output disabled
1
Strobe output enabled
R
TRF
Status of automatic transmit/receive function
Detection of termination of automatic transmission/
reception (This bit is set to 0 upon suspension of
0
automatic transmission/reception or when ARLD = 0.)
During automatic transmission/reception
1
(This bit is set to 1 when data is written to SIO1.)
R
ERR
Error detection of automatic transmit/receive
function
No error
0
(This bit is set to 0 when data is written to SIO1.)
1
Error occurred
ERCE
Error check control of automatic transmit/
receive function
0
Error check disabled
1
Error check enabled (only when BUSY1 = 1)
ARLD
Operating mode selection of automatic transmit/
receive function
0
Single operating mode
1
Repetitive operating mode
RE
Receive control of automatic transmit/receive
function
0
Receive disabled
1
Receive enabled
R/W