Mode Control Motor
Test
1 .
2.
Disconnect the 7P connector trom the mode control
motor.
Connect battery power to the No. 1 terminal, and
g r o u n d t h e N o , 7 t e r m i n a l .
CAUTION: Never connect the battery in the oppo-
site direction.
U s i n g a j u m p e r w i r e , c o n n e c t t h e N o . 7 t e r m i n a l
individually to the No. 2, 3, 4, 5 and 6 terminals in
that order. Each time the connection is made' the
mode control motor should run smoothly and stop.
NOTE: It the mode control motor does not run when
jumping the first terminal, jump that terminal again
after jumping the other terminals. The mode control
motor is OK it it runs when jumping the first termi-
n a l a g a i n .
MOOE CONTROL MOTOR
4.
lf the mode control motor does not run in step 3,
remove it, then check the mode control linkage and
doors Ior smooth movement. lf they move smoothly,
replace the mode control motor.
21-24
Replacement
1 . Disconnect the 7P connector from the mode control
motor.
Remove the rod from the arm of the mode control
motor.
Bemove the two self-tapping screws and the mode
control motor.
Install in the reverse order of removal. After installa-
t i o n , m a k e s u r e t h e m o d e c o n t r o l m o t o r r u n s
smoothlv.
7P CONNECTOR