Chapter 5: Enabler Installation And Configuration; Introduction; Installation; Installing The Enabler On Mobile Devices - Honeywell Thor VM1 Reference Manual

Vehicle-mounted computer, microsoft windows embedded ce 6 operating system
Hide thumbs Also See for Thor VM1:
Table of Contents

Advertisement

Chapter 5: Enabler Installation and Configuration

Introduction

This section discusses Honeywell supported features with Wavelink Avalanche Mobile Device Servers. This section is split
into three basic areas:

Installation

l
User Interface
l
Enabler Configuration
l
Installation
To use the Wavelink Avalanche MC System, the following items are required:
A desktop or laptop PC on which to install the Avalanche MC Console.
l
A desktop or laptop PC on which to install the Avalanche Mobile Device Server (this can be the same PC where the
l
Avalanche MC Console is installed).
Wavelink Avalanche MC Console 4.2 or later.
l
A Wavelink Device License for each client device.
l
To use Avalanche Remote Control, the follow additional items are required:
Wavelink Remote Control plug-in, 2.0 or later
l
A Wavelink Remote Control License for each client device
l

Installing the Enabler on Mobile Devices

Supported devices have the Avalanche Enabler installation files loaded, but not installed, on the mobile device when it is
shipped. The installation files are located in the \System folder on Windows devices.
Note:
Important: If the user is NOT using Wavelink Avalanche to manage their mobile device(s), the
Enabler should not be installed on the mobile device(s). Doing so results in unnecessary delays when
booting the device.
The Avalanche Enabler installation file LXE_ENABLER.CAB is loaded on the Thor VM1 by Honeywell; however, the device is
not configured to launch the Enabler installation file automatically. The installation application must be run manually the first
time Avalanche is used.
After installation, the Enabler runs as a background application monitoring for updates. This behavior can be modified by
accessing the Avalanche Update Settings panel through the Enabler interface.
This behavior can be modified by accessing the Avalanche Update Settings panel through the Enabler Interface.
The RMU.CE.CAB file is placed on the device during manufacturing in the \System\RMU folder.
During the Enabler installation process, the Enabler checks for the RMU.CE.CAB file in the \System folder.
If present, it assumes the RMU.CE.CAB file is already installed and continues.
l
If the file RMU.CE.CAB file is not present, it looks for the file in the \System\RMU folder.
l
If present, the Enabler copies the file to the \System folder and installs it.
l
At this point, the OS will automatically install the Remote Management Utility (RMU) after the Thor VM1 reboots.
5-1

Advertisement

Table of Contents
loading

Table of Contents