Table B–10: MODBUS MEMORY MAP (Sheet 57 of 58)
ADDR
REGISTER NAME
DF42
...Repeated for Contact Output 47
DF51
...Repeated for Contact Output 48
DF60
...Repeated for Contact Output 49
DF6F
...Repeated for Contact Output 50
DF7E
...Repeated for Contact Output 51
DF8D
...Repeated for Contact Output 52
DF9C
...Repeated for Contact Output 53
DFAB
...Repeated for Contact Output 54
DFBA
...Repeated for Contact Output 55
DFC9
...Repeated for Contact Output 56
DFD8
...Repeated for Contact Output 57
DFE7
...Repeated for Contact Output 58
DFF6
...Repeated for Contact Output 59
E005
...Repeated for Contact Output 60
E014
...Repeated for Contact Output 61
E023
...Repeated for Contact Output 62
E032
...Repeated for Contact Output 63
E041
...Repeated for Contact Output 64
DCmA Inputs (Read/Write Setting) (24 modules)
E050
DCmA Inputs 1 Function
E051
DCmA Inputs 1 ID
E057
Reserved (4 items)
E05B
DCmA Inputs 1 Units
E05E
DCmA Inputs 1 Range
E05F
DCmA Inputs 1 Minimum Value
E061
DCmA Inputs 1 Maximum Value
E063
...Repeated for DCmA Inputs 2
E076
...Repeated for DCmA Inputs 3
E089
...Repeated for DCmA Inputs 4
E09C
...Repeated for DCmA Inputs 5
E0AF
...Repeated for DCmA Inputs 6
E0C2
...Repeated for DCmA Inputs 7
E0D5
...Repeated for DCmA Inputs 8
E0E8
...Repeated for DCmA Inputs 9
E0FB
...Repeated for DCmA Inputs 10
E10E
...Repeated for DCmA Inputs 11
E121
...Repeated for DCmA Inputs 12
E134
...Repeated for DCmA Inputs 13
E147
...Repeated for DCmA Inputs 14
E15A
...Repeated for DCmA Inputs 15
E16D
...Repeated for DCmA Inputs 16
E180
...Repeated for DCmA Inputs 17
E193
...Repeated for DCmA Inputs 18
E1A6
...Repeated for DCmA Inputs 19
E1B9
...Repeated for DCmA Inputs 20
E1CC
...Repeated for DCmA Inputs 21
E1DF
...Repeated for DCmA Inputs 22
E1F2
...Repeated for DCmA Inputs 23
E205
...Repeated for DCmA Inputs 24
DNP/IEC Points (Read/Write Setting)
E700
DNP/IEC 60870-5-104 Binary Input Points (256 items)
E900
DNP/IEC 60870-5-104 Analog Input Points (256 items)
Synchrocheck (Read/Write Setting) (4 modules)
EC00
Synchrocheck 1 Function
GE Multilin
RANGE
0 to 1
---
0 to 65535
---
0 to 6
-9999.999 to 9999.999
-9999.999 to 9999.999
0 to 4294967295
0 to 65535
0 to 1
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
---
F205
---
1
F001
---
---
F206
---
1
F173
6 (4 to 20 mA)
---
0.001
F004
---
0.001
F004
---
1
F300
---
1
F600
---
1
F102
DEFAULT
B
0 (Disabled)
"DCMA Ip 1 "
0
"mA"
4000
20000
0
0
0 (Disabled)