GE D30D00HCHF8AH6AM6BP8BX7A Instruction Manual page 522

Ur series line distance protection system
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 40 of 58)
ADDR
REGISTER NAME
AA7E
...Repeated for IEC 61850 GOOSE Analog Input 19
AA85
...Repeated for IEC 61850 GOOSE Analog Input 20
AA8C
...Repeated for IEC 61850 GOOSE Analog Input 21
AA93
...Repeated for IEC 61850 GOOSE Analog Input 22
AA9A
...Repeated for IEC 61850 GOOSE Analog Input 23
AAA1
...Repeated for IEC 61850 GOOSE Analog Input 24
AAA8
...Repeated for IEC 61850 GOOSE Analog Input 25
AAAF
...Repeated for IEC 61850 GOOSE Analog Input 26
AAB6
...Repeated for IEC 61850 GOOSE Analog Input 27
AABD
...Repeated for IEC 61850 GOOSE Analog Input 28
B
AAC4
...Repeated for IEC 61850 GOOSE Analog Input 29
AACB
...Repeated for IEC 61850 GOOSE Analog Input 30
AAD2
...Repeated for IEC 61850 GOOSE Analog Input 31
AAD9
...Repeated for IEC 61850 GOOSE Analog Input 32
IEC 61850 XCBR Configuration (Read/Write Settings and Commands) (6 modules)
AB00
Operand for IEC 61850 XCBR1.ST.Loc Status
AB02
Command to Clear XCBR1 OpCnt (Operation Counter)
AB03
Operand for IEC 61850 XCBR2.ST.Loc Status
AB05
Command to Clear XCBR2 OpCnt (Operation Counter)
AB06
Operand for IEC 61850 XCBR3.ST.Loc Status
AB08
Command to Clear XCBR3 OpCnt (Operation Counter)
AB09
Operand for IEC 61850 XCBR4.ST.Loc Status
AB0B
Command to Clear XCBR4 OpCnt (Operation Counter)
AB0C
Operand for IEC 61850 XCBR5.ST.Loc Status
AB0E
Command to Clear XCBR5 OpCnt (Operation Counter)
AB0F
Operand for IEC 61850 XCBR6.ST.Loc Status
AB11
Command to Clear XCBR6 OpCnt (Operation Counter)
IEC 61850 LN Name Prefixes (Read/Write Settings)
AB30
IEC 61850 Logical Node LPHD1 Name Prefix
AB33
IEC 61850 Logical Node PIOCx Name Prefix (72 items)
AC0B
IEC 61850 Logical Node PTOCx Name Prefix (24 items)
AC53
IEC 61850 Logical Node PTUVx Name Prefix (13 items)
AC7A
IEC 61850 Logical Node PTOVx Name Prefix (10 items)
AC98
IEC 61850 Logical Node PDISx Name Prefix (10 items)
ACB6
IEC 61850 Logical Node RBRFx Name Prefix (24 items)
ACFE
IEC 61850 Logical Node RPSBx Name Prefix
AD01
IEC 61850 Logical Node RRECx Name Prefix (6 items)
AD13
IEC 61850 Logical Node MMXUx Name Prefix (6 items)
AD25
IEC 61850 Logical Node GGIOx Name Prefix (5 items)
AD34
IEC 61850 Logical Node RFLOx Name Prefix (5 items)
AD43
IEC 61850 Logical Node XCBRx Name Prefix (6 items)
AD55
IEC 61850 Logical Node PTRCx Name Prefix (6 items)
AD67
IEC 61850 Logical Node PDIFx Name Prefix (4 items)
AD73
IEC 61850 Logical Node MMXNx Name Prefix (37 items)
ADE2
IEC 61850 Logical Node CSWIx Name Prefix (30 items)
AE3C
IEC 61850 Logical Node XSWIx Name Prefix (24 items)
IEC 61850 GGIO4 General Analog Configuration Settings (Read/Write Setting)
AF00
Number of Analog Input Points in GGIO4
IEC 61850 GGIO4 Analog Input Points Configuration Settings (Read/Write Setting) (32 modules)
AF10
IEC 61850 GGIO4 Analog Input 1 Value
AF11
IEC 61850 GGIO4 Analog Input 1 Deadband
AF13
IEC 61850 GGIO4 Analog Input 1 Minimum
AF15
IEC 61850 GGIO4 Analog Input 1 Maximum
B-48
RANGE
0 to 4294967295
0 to 1
0 to 4294967295
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 1
0 to 65535
0 to 1
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
4 to 32
---
0.001 to 100
–1000000000000 to
1000000000000
–1000000000000 to
1000000000000
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F300
---
1
F126
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
4
F001
---
---
F600
%
0.001
F003
---
0.001
F060
---
0.001
F060
DEFAULT
0
0 (No)
0
0 (No)
0
0 (No)
0
0 (No)
0
0 (No)
0
0 (No)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
4
0
100000
0
1000000
GE Multilin

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30

Table of Contents