GE D30D00HCHF8AH6AM6BP8BX7A Instruction Manual page 498

Ur series line distance protection system
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 16 of 58)
ADDR
REGISTER NAME
3FF7
...Repeated for Field Unit 8
Passwords (Read/Write Command)
4000
Command Password Setting
Passwords (Read/Write Setting)
400A
Setting Password Setting
Passwords (Read/Write)
4014
Command Password Entry
401E
Setting Password Entry
Passwords (Read Only)
4028
Command Password Status
B
4029
Setting Password Status
Passwords (Read/Write Setting)
402A
Command Password Access Timeout
402B
Setting Password Access Timeout
402C
Invalid Password Attempts (before lockout)
402D
Password Lockout Duration
Passwords (Read/Write)
402E
Password Access Events
Passwords (Read/Write Setting)
402F
Local Setting Auth
4031
Remote Setting Auth
4033
Access Auth Timeout
User Display Invoke (Read/Write Setting)
4040
Invoke and Scroll Through User Display Menu Operand
LED Test (Read/Write Setting)
4048
LED Test Function
4049
LED Test Control
Preferences (Read/Write Setting)
404F
Language
4050
Flash Message Time
4051
Default Message Timeout
4052
Default Message Intensity
4053
Screen Saver Feature
4054
Screen Saver Wait Time
4055
Current Cutoff Level
4056
Voltage Cutoff Level
Communications (Read/Write Setting)
407D
COM2 Selection
407E
COM1 Minimum Response Time
407F
COM2 Minimum Response Time
4080
Modbus Slave Address
4083
RS485 Com1 Baud Rate
4084
RS485 Com1 Parity
4085
RS485 Com2 Baud Rate
4086
RS485 Com2 Parity
4087
Port 1 IP Address
4089
Port 1 IP Subnet Mask
408B
Port 1 Gateway IP Address
408D
Network Address NSAP
4097
Reserved
4098
Port 2 Link Loss Alert
4099
Port 3 Link Loss Alert
409A
DNP Channel 1 Port
409B
DNP Channel 2 Port
B-24
RANGE
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
5 to 480
5 to 480
2 to 5
5 to 60
0 to 1
1 to 4294967295
0 to 4294967295
5 to 480
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4
0.5 to 10
10 to 900
0 to 3
0 to 1
1 to 65535
0.002 to 0.02
0.1 to 1
0 to 3
0 to 1000
0 to 1000
1 to 254
0 to 11
0 to 2
0 to 11
0 to 2
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 1
0 to 1
0 to 1
0 to 5
0 to 5
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F202
---
1
F202
---
1
F202
---
1
F202
---
1
F102
---
1
F102
min
1
F001
min
1
F001
---
1
F001
min
1
F001
---
1
F102
---
1
F300
---
1
F300
min
1
F001
---
1
F300
---
1
F102
---
1
F300
---
1
F531
s
0.1
F001
s
1
F001
---
1
F101
---
1
F102
min
1
F001
pu
0.001
F001
V
0.1
F001
---
1
F601
ms
10
F001
ms
10
F001
---
1
F001
---
1
F112
---
1
F113
---
1
F112
---
1
F113
---
1
F003
---
1
F003
---
1
F003
---
---
F074
---
1
F102
---
1
F102
---
1
F102
---
1
F177
---
1
F177
DEFAULT
(none)
(none)
(none)
(none)
0 (Disabled)
0 (Disabled)
5
30
3
5
0 (Disabled)
1
1
30
0
0 (Disabled)
0
0 (English)
10
300
0 (25%)
0 (Disabled)
30
20
10
0 (RS485)
0
0
254
8 (115200)
0 (None)
8 (115200)
0 (None)
56554706
4294966272
56554497
0
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (None)
0 (None)
GE Multilin

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30

Table of Contents