Cisco TelePresence MX700 and MX800
Introduction
SerialPort configuration
xConfiguration SerialPort Mode
Enable/disable the serial port (COM port).
Requires user role: ADMIN, INTEGRATOR
Default value: On
USAGE:
xConfiguration SerialPort Mode:
where
Mode
: Off/On
Off: Disable the serial port.
On: Enable the serial port.
xConfiguration SerialPort BaudRate
Define the baud rate (data transmission rate, bits per second) for the serial port.
Other connection parameters for the serial port are: Data bits: 8; Parity: None; Stop bits: 1; Flow
control: None.
Requires user role: ADMIN, INTEGRATOR
Default value: 115200
USAGE:
xConfiguration SerialPort BaudRate:
where
BaudRate
: 9600/19200/38400/57600/115200
Set a baud rate from the baud rates listed (bps).
D15335.08 Cisco TelePresence MX700 and MX800 API Reference Guide CE9.2, NOVEMBER 2017.
About the API
xConfiguration
xConfiguration
Mode
BaudRate
xCommand
xConfiguration SerialPort LoginRequired
Define if login shall be required when connecting to the serial port.
Requires user role: ADMIN
Default value: On
USAGE:
xConfiguration SerialPort LoginRequired:
where
LoginRequired
: Off/On
Off: The user can access the codec via the serial port without any login.
On: Login is required when connecting to the codec via the serial port.
87
API Reference Guide
xStatus
Appendices
LoginRequired
Copyright © 2017 Cisco Systems, Inc. All rights reserved.