Functions, Codes And Symbols - ABB RED615 Technical Manual

615 series
Hide thumbs Also See for RED615:
Table of Contents

Advertisement

Section 1
Introduction
1.4.3
28
To navigate between the options, use
HMI menu paths are presented in bold.
Select Main menu/Settings.
LHMI messages are shown in Courier font.
To save the changes in non-volatile memory, select Yes and press
Parameter names are shown in italics.
The function can be enabled and disabled with the Operation setting.
Parameter values are indicated with quotation marks.
The corresponding parameter values are "On" and "Off".
IED input/output messages and monitored data names are shown in Courier font.
When the function starts, the START output is set to TRUE.

Functions, codes and symbols

All available functions are listed in the table. All of them may not be applicable to
all products.
Table 1:
Functions included in the IEDs
Function
Protection
Three-phase non-directional overcurrent protection,
low stage, instance 1
Three-phase non-directional overcurrent protection,
low stage, instance 2
Three-phase non-directional overcurrent protection,
high stage, instance 1
Three-phase non-directional overcurrent protection,
high stage, instance 2
Three-phase non-directional overcurrent protection,
instantaneous stage, instance 1
Three-phase non-directional overcurrent protection,
instantaneous stage, instance 2
Three-phase directional overcurrent protection, low
stage, instance 1
Three-phase directional overcurrent protection, low
stage, instance 2
Three-phase directional overcurrent protection, high
stage
Three-phase non-directional overcurrent protection
that contains three independent phase-segregated
timers, low stage, instance 1
Three-phase non-directional overcurrent protection
that contains three independent phase-segregated
timers, low stage, instance 2
Three-phase non-directional overcurrent protection
that contains three independent phase-segregated
timers, high stage, instance 1
Three-phase non-directional overcurrent protection
that contains three independent phase-segregated
timers, high stage, instance 2
Three-phase non-directional overcurrent protection
that contains three independent phase-segregated
timers, instantaneous stage, instance 1
Three-phase directional overcurrent protection that
contains three independent phase-segregated timers,
low stage, instance 1
Table continues on next page
and
.
IEC 61850
IEC 60617
PHLPTOC1
3I> (1)
PHLPTOC2
3I> (2)
PHHPTOC1
3I>> (1)
PHHPTOC2
3I>> (2)
PHIPTOC1
3I>>> (1)
PHIPTOC2
3I>>> (2)
DPHLPDOC1
3I> -> (1)
DPHLPDOC2
3I> -> (2)
DPHHPDOC1
3I>> ->
PH3LPTOC1
3I> (1)
PH3LPTOC2
3I> (2)
PH3HPTOC1
3I>> (1)
PH3HPTOC2
3I>> (2)
PH3IPTOC1
3I>>> (1)
DPH3LPDOC1
3I> -> (1)
1YHT530004D05 D
.
IEC-ANSI
51P-1 (1)
51P-1 (2)
51P-2 (1)
51P-2 (2)
50P/51P (1)
50P/51P (2)
67-1 (1)
67-1 (2)
67-2
51P-1 (1)
51P-1 (2)
51P-2 (1)
51P-2 (2)
50P/51P (1)
67-1 (1)