Cisco Ip Phone 8800 Series Administration Guide For Cisco Unified Communications Manager - Cisco 8800 Series Administration Manual

Hide thumbs Also See for 8800 Series:
Table of Contents

Advertisement

Phone Feature Configuration
Field
Enable Audible Alert
EnergyWise Domain
EnergyWise Secret
Allow EnergyWise Overrides

Cisco IP Phone 8800 Series Administration Guide for Cisco Unified Communications Manager

212
Description
When enabled, instructs the phone to play an audible alert starting 10 minutes before the time
that the Phone Off Time field specifies.
The audible alert uses the phone ringtone, which briefly plays at specific times during the
10-minute alerting period. The alerting ringtone plays at the user-designated volume level. The
audible alert schedule is:
• At 10 minutes before power down, play the ringtone four times.
• At 7 minutes before power down, play the ringtone four times.
• At 4 minutes before power down, play the ringtone four times.
• At 30 seconds before power down, play the ringtone 15 times or until the phone powers
off.
This check box applies only if the Enable Power Save Plus list box has one or more days selected.
The EnergyWise domain that the phone is in.
The maximum length of this field is 127 characters.
The security secret password that is used to communicate with the endpoints in the EnergyWise
domain.
The maximum length of this field is 127 characters.
This check box determines whether you allow the EnergyWise domain controller policy to send
power level updates to the phones. The following conditions apply:
• One or more days must be selected in the Enable Power Save Plus field.
• The settings in Cisco Unified Communications Manager Administration take effect on
schedule even if EnergyWise sends an override.
For example, assuming the Phone Off Time is set to 22:00 (10:00 p.m.), the value in the Phone
On Time field is 06:00 (6:00 a.m.), and the Enable Power Save Plus has one or more days selected.
• If EnergyWise directs the phone to turn off at 20:00 (8:00 p.m.), that directive remains in
effect (assuming no phone user intervention occurs) until the configured Phone On Time
at 6:00 a.m.
• At 6:00 a.m., the phone turns on and resumes receiving the power level changes from the
settings in Unified Communications Manager Administration.
• To change the power level on the phone again, EnergyWise must reissue a new power level
change command.
To disable Power Save Plus, you must uncheck the Allow EnergyWise Overrides check
Note
box. If the Allow EnergyWise Overrides remains checked but no days are selected in
the Enable Power Save Plus field, Power Save Plus is not disabled.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents