Downloading; Installation; External Connections - Bosch DCN Next Generation Installation & User's Instructions

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN Next Generation | Installation and User Instructions | Central Devices
10.4

Downloading

To download the software do the following:
1 Install the download and license tool on a PC (the
download and license tool is on the CD).
2 Connect all central equipment to the network
controller, except the CCUs.
3 Connect the PC to the network controller.
4 Set the PC communication port to network
connection.
5 Configure the correct IP address (refer to section
10.10.13).
6 Download the network controller.
7 Download optical devices.
8 Set the PC communications port to serial
connection.
9 Disconnect all CCUs.
10 Select the correct serial port and baud rate of each
CCU (refer to section 8.3.3).
11 Connect the CCUs, one at a time, to the PC.
12 Download to the CCU: "software for wired DCN"
(refer to section 8.6).
Note
Do not change the language selection when
downloading the CCUs.
Note
For the system to work correctly, all software
and firmware of the central equipment and PC
must be of the same release.
Note
If you connect the network controller via a
network, check with your IT department which IP
address to use.
Bosch Security Systems | 2007-02 | 9922 141 70525
10.5

Installation

Refer to section 8.4 for information about the
installation of the network controller. The procedures to
install the central control unit and the network
controller are the same.
10.6

External connections

10.6.1 Power supply
To connect the network controller to a mains power
supply proceed as follows:
1 Set the voltage selector on the rear of the network
controller to the correct position (refer to table 10.2).
table 10.2: Voltage selector
Power supply voltage
90 to 132 V(AC)
198 to 264 V(AC)
2 Make sure that the fuse holder in the rear of the
network controller contains the correct fuse (refer to
table 10.3).
table 10.3: Fuses
Voltage selector
Fuse
115
T2.5A 250 V (UL 248)
230
T2AH 250 V (IEC 60127)
3 Connect a locally approved power cable to the
network controller.
4 Connect the power cable to a power supply.
Caution
Make sure that the mains power supply is
grounded. Electrical discharges from the mains
power supply can kill you.
en | 80
Voltage selector
115
230

Advertisement