DCN Next Generation | Installation and User Instructions | Central Devices
13.2.2 Rear view
The rear of the cobranet interface (refer to figure 13.1)
contains:
4 Optical network sockets - Connect the cobranet
interface to the optical network (refer to section
13.4.1).
5 CobraNet sockets - Connect the cobranet
interface to the CobraNet network (refer to section
13.4.3). The CobraNet network contains the audio
inputs and the audio outputs of the cobranet
interface.
6 Control inputs - Connect the cobranet interface to
external devices. Through the control inputs,
external devices can control the audio inputs and the
audio outputs of the cobranet interface (refer to
section 13.4.5).
7 Control outputs - Send the condition of the
cobranet interface to external devices (refer to
section 13.4.6).
Bosch Security Systems | 2007-02 | 9922 141 70525
13.3

Installation

You can install the cobranet interface in a 19-inch rack
system or on a flat surface. Four feet and two brackets
are supplied along with the cobranet interface (refer to
figure 13.2).
figure 13.2: Installation
table 13. 1 : Physical characteristics
Dimensions (h x w x d), flat surface
92 x 440 x 400 mm (without brackets, with feet)
Dimensions (h x w x d), 19-inch rack system
88 x 483 x 400 mm (with brackets, without feet)
Weight:
7.0 kg (without brackets, without feet).
Note
If you install the cobranet interface in a 19-inch
rack system, the cobranet interface extends
36 mm in front of the brackets.