Wiring; Custom-Made Cables; Technical Data - Bosch DCN Next Generation Installation & User's Instructions

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN Next Generation | Installation and User Instructions | Installation Devices

43.3 Wiring

Refer to figure 43.4 for details about the wires inside the
extension cables.
3
2
1
figure 43.4 Wires
table 43.3: Wires
Number
Signal
1
Protective cloth
2
Insulation
3
Outer sheet
4
Stranded wire
5
Optical fiber

43.4 Custom-made cables

Use the LBB4418/00 Cable-connector Tool Kit to make
cables from LBB4416/00 Optical Network Cables and
LBB4417/00 Optical Network Connectors.
Bosch Security Systems | 2007-02 | 9922 141 70525
4
5
7±0. 1

43.5 Technical data

table 43.4: Technical data
Insulation:
LSZH (low smoke/zero halogen), black
Outer diameter:
7 mm
Power supply wires (2):
2
Copper, stranded 1 mm
resistance < 0.018 Ω/m
Optical fibers:
PMMA, 1 mm diameter includes cladding, 2 mm
diameter includes insulation (black)
Numeric aperture: 0.5
Optical attenuation < 0. 1 7 dB/m @ 650 nm
Bending loss < 0.5 dB (r = 20 mm, 90°),
according to JIS C6861
Temperature range:
-40 to 65 °C
Pull force:
max. 150 N
Flame retardant:
According to IEC 60332-1 / 60 s
Halogen level:
According to IEC 60754-2, pH > 4.3 and
conductivity < 10 uS/mm
Smoke level:
According to IEC 61034-2, light transmittance > 60%
en | 239