SAMSUNG DCS
TECHNICAL MANUAL
MMC 307:
DESCRIPTION:
Allows a station the ability to make a predetermined outgoing call, eg., 000, upon the expiration of a timer
(see MMC 501 System Timers, Off-Hook Selection Timer). There is a maximum of 18 digits dialled with
pauses, FLASH, and Decadic to DTMF dial mode change may be included in the dial string. The access code
for the trunk is not counted.
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
HOLD
B
C
D
E
ACTION
1.
Press TRSF 307
Display shows
2.
Dial station number
Use UP or DOWN to scroll through station
numbers and press RIGHT soft key to move
the cursor
3.
Dial telephone number with an access code
or trunk ID (eg., 0 or 701) with a maximum
of 18 outgoing digits after the access code
(see above list of options if needed)
Bottom row of program keys are options
B-E. Press RIGHT soft key to
advance cursor to step 4
4.
Dial a 1 for YES or 0 for NO
Press UP or DOWN key to select YES/NO
option.
Press RIGHT soft key to return to step 2
5.
Press TRSF to store and exit
Press SPK to store and advance to next
MMC
DEFAULT DATA:
RELATED ITEMS:
Page 74 of 287 Updated I&M
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
Used to clear previous entry
Used to insert a flash code "F"
Used to insert a pause code "P"
Used to insert a pulse/tone conversion code "C"
Used to mask/unmask following digits - shows as "[ ]" whilst programming,
and "∗" on station when using this facility.
OR
OR
OR
CURRENTLY SET = NO
MMC 501 SYSTEM TIMERS, OFF-HOOK SELECTION TIMER
Assign Off-Hook Selection
DISPLAY
[201]
[205]
_
[205]
0-1305P4264100_
[205]
CURRENTLY SET : YES
PROGRAMMING
SECTION
OFFHK
SEL.
OFFHK
SEL.
OFFHK
SEL.
OFFHK
SEL.
May 2002

Advertisement

loading